ITEM |
Installation position |
Connector |
Standard |
Rated current |
Rated Voltage |
Cable specification |
KLS15-IEC04-E16 |
Electric vehicle |
JACK |
IEC 62196-2 |
16A |
250V |
3*2.5mm2+2*0.75mm2 |
KLS15-IEC04-D16 |
Electric vehicle |
JACK |
IEC 62196-2 |
16A |
415V |
5*2.5mmm2+2*0.75mm2 |
KLS15-IEC04-E32 |
Electric vehicle |
JACK |
IEC 62196-2 |
32A |
250V |
3*6mm2+2*0.75mm2 |
KLS15-IEC04-D32 |
Electric vehicle |
JACK |
IEC 62196-2 |
32A |
415V |
5*6mm2+2*0.75mm2 |
Features
1.Meet 62196-2 IEC 2010 SHEET 2-IIf standards
2.Nice appearance, with protective cover, support front installation
3. Safety pins insulated head design to prevent accidental direct contact with staff
4. Excellent protection performance, protection grade IP44(working condition)
Mechanical properties
Mechanical life: no load-plug in/pull out> 10000times
Electrical performance
1. Rated operating current: 16A/32A
2. Working Voltage: 250/415V AC
3. Insulation resistance:> 1000MΩ (DC500V)
4. Terminal temperature rise: <50K
5. Withstand voltage: 2000V
6. Contact resistance: 0.5mΩ Max
Material application
1.Case Material: thermoplastic flammability rating UL94V-0
2.Pin: copper alloy, the surface of the silver-plated + top of thermoplastics
Environmental performance
Operating temperature: -30 ° C ~ +50 ° C |