> Sensing distance: Fiber-optic sensors and fibers,Depends on Optical fiber head
> Output: NPN+PNP
> Housing material: PC+ABS
> Connection: Cable
> Supply voltage: 12-24VDC
> Response time: <1ms
| Light source |
Visible red light |
| Output ways |
NPN+PNP |
| Voltage drop |
<2.5V(@ILOAD=100mA) |
| Output delay |
Can be set (NORM: output no delay; OFF DLY 100ms: output shutdown delay 100ms) |
| Supply Voltage |
10…30 VDC |
| Fluctuation voltage |
<40mA |
| Load current |
≤100mA |
| Current consumption |
<0.1mA |
| Dielectric properties |
<0.2mA(500VAC, 60s) |
| Response time |
<1ms |
| Hysteresis |
3%-20% |
| Repeat accuracy |
<5% |
| Temperature drift |
<10% |
| Ambient temperature |
0℃~50℃ |
| Power supply protection |
Short circuit protection |
| Output protection |
Overload protection, short circuit protection |
| Shock resistance |
Impact (pulse) waveform: half sine; peak speed: 30gn; pulse duration; 11ms |
| Vibration resistance |
Amplitude: 1mm; frequency: 10~55Hz; sweep period: 5min) |
| Protection degree |
IP54 |
| Effective operating distance |
1~80mm (using white card with 90% reflectivity, 100*100mm size, fiber optic cable PRC-610) |
| Indicator display |
Output indication, power indication, stability indication, short circuit\overload indication, setting indication |
| Sensing distance adjustment |
button |
| Housing material |
PC+ABS |
| EMC-ESD |
±4kV CD/±8kV AD(IEC61000-4-2) |
| EMC-Burst |
±2kV 5kHz(IEC61000-4-4) |
| EMC-HF radiated/conducted |
3V/m(IEC61000-4-3)/3V(IEC61000-4-6) |
| Connection |
Cable |
|
| Picture |
Part No. |
PDF |
Description |
Order Qty. |
Time |
Order |
|
|